OGP Portable Dissolved Oxygen Meter Ozone Analyzer

1 Piece
MOQ
OGP Portable Dissolved Oxygen Meter Ozone Analyzer
Caratteristiche Galleria Descrizione di prodotto Richieda una citazione
Caratteristiche
Specificazioni
Type: Double UV light
Model Number: OGP
Detection range: 0-200 g/m3 (extensible 0~350mg/L)
Model number: OGP-UV2100C
Measurement method: Double UV light absorption with high precision measurement
Light source system: German long-life ultraviolet lamp (253.7 nm wavelength)
Informazioni di base
Model Number: OGP, OGP-UV2100C
Termini di pagamento e spedizione
Packaging Details: carton case or wooden case
Supply Ability: 50 Piece/Pieces per Month
Descrizione di prodotto

Portable dissolved oxygen meter ozone analyzer

Specification
Model OGP-UV2300
Measurement method:UV light double optical receiver with high precision measurement
Light source systemGerman long-life ultraviolet lamp (253.7 nm wavelength)
Detection range0-200 g/m3 (extensible 0~350mg/L)
Display resolution0.01 g/m3
Input gas flow1.2L±0.2L/min
Input pressure<0.1MPa
Zero shift< ±0.1%.FS(MAX:±0.3 g/m3);
Responsive time<2S
Sampling port diameterΦ6(6mm*4mm)
The accuracy of detection±3% readings
Communication modeRS-485
Output mode4-20mA,linearity
PowerAC 220V
Size:330*230*150mm
Weight5kg
Remaks1mg/L=1g/m3=467PPM
Warranty 2 years
OGP-UV2100 Ozone Detector For Ozone Output Of Ozone Generator
Model OGP-UV2100
Measurement method:UV light double optical receiver with high precision measurement
Light source systemGerman long-life ultraviolet lamp (253.7 nm wavelength)
Detection range0-200 g/m3 (extensible 0~350mg/L)
Display resolution0.01 g/m3
Input gas flow1.2L±0.2L/min
Input pressure<0.1MPa
Zero shift< ±0.1%.FS(MAX:±0.2 g/m3);
Working voltage110~220V
Responsive time<2S
Sampling port diameterΦ6(6mm*4mm)
The accuracy of detection±3% readings
Communication modeRS-485
Output mode4-20mA,linearity
PowerAC 220V
Size:155*78*240mm
Hole size:145*68
Weight2kg
Remaks1mg/L=1g/m3=467PPM
Warranty 1 years
Portable Ozone Analyzer for space room

Gas Detected

OGP-O3SL

Detection principle

According to electro-chemical principle

Sampling Method

pumping style,flow 1L/min,there are 10 grears to adjust the suction of pump

Measure Range

0-1ppm,0-5ppm,0-10ppm,0-20ppm,0-50ppm,0-100ppm,0-200ppm,0-500ppm,0-1000ppm for option

Resolution

0.001ppm(0-1ppm),0.01ppm(0-100ppm),0.1ppm(0-200ppm,0-500ppm),1ppm(0-1000ppm)

Precision

2%FS

Signal Output

USB high speed data transmission,Downloadable print data (optional)

Response Time

≤10S

Recovery Time

≤10S

Repeatability

≤±1%

Linearity error

≤±1%

Zero shift

≤±1%(F.S/year)

Display

LCD dot matrix display technology

Operating language

Chinese , English

Alarm mode

Sound, light, vibration

Temperature

-40℃~70℃

Humidity

0-95%RH

Explosion-Proof

ExiaⅡCT4

Degree of protection

IP66

Dimensions

205*75*32mm

Weight

300g

CL7685 Ozone water detector for ozone concentration in water

Specifications

Input Current : 2 µA/PPM at 20 °C

Scales
0/2.000 PPM - 0/20.00 PPM
(Cl2, ClO2, D.O3)
Zero adjustment: +/- 0.3 µA
Cell sensitivity: 12.5/250 %
Polarization: -200 mV (0/-1250 mV)
Temperature coefficient: 0/4.0%/°C

Filter software 90% RT: 0.4/20.0 s for small/large variations

Temperature
Input: Pt100 3 wires
Measuring and compensation range: -2/52°C
Resolution: 0.1 °C
Zero adjustment: +/- 1 °C

Set-point A and B
Selectable action: ON/OFF - PFM – PWM

PFM/PWM action

Proportional band: 0/10% of the scale
Pulse frequency: 0/120 pulse/min
Pulse width: 0/99.9 s

DOZ5000 Ozone water detector for ozone concentration in water

measuring range

0-2.000 ppm; 0-20.00 ppm

Resolution / accuracy

0.001ppm; 0.01ppm /±2% of full measuring range

Zero adjustment:

1(0%) or 2

temperature range

-5.0~+100 °C

temperature compensation

ATC automatic/ MTC manual operation

Resolution/precision

0.1 °C / ± 0.5 °C

Sensor

Electrode dissolved ozone sensor

Temperature input

NTC22K

Control type

ON/OFF control (LIT) / Proportional pulse width control(PLC)

Signal output/load

0/4 - 20mA / 600Ω

Data interface

RS-485

Relay / specification

3 SPST / 250V 1A ( Or 110V 2A)

Hysteresis width of High and low point

0.01 - 2.00ppm / 0.1 - 20.0%

Cleaning period/ time of duration

1 - 999hours / 1 - 999S

Screen

Multi-line LCD,Orange LED back light

Power

220 VAC

EMC grade

EN 50081-1 / EN 50082-1

Ambient temperature limits

-10~+50 °C (14~122 °F)

Environmental humidity limit

10 - 95% (No condensation)

level of protection

NEMA4X,IP 65

Size W*H*D

100 * 108 * 150mm

installation method

Dial plate installation

Cutting size of dial plate installation

93.5 * 93.5mm

Weight

900g

OGP-EC Online Ozone Detector for space room
Gas Detected(O3)
Detection principleElectro-chemical principle
Sampling MethodWall mounted, pipeline, circulation type (related to monitor the environment)
Measure Range0-1ppm,0-5ppm,0-10ppm,0-20ppm,0-50ppm,0-100ppm,0-200ppm,0-500ppm,0-1000ppm(range for option,not listed range can be customized)
Resolution0.001ppm,0.01ppm,0.1ppm,1ppm(The resolution is associated with the selected range)
Precision2%FS
Output signal4-20MA,0-5V,RS485,RS232,,Timer,wireless digital(for option)
Response Time≤10S
Repeatability≤±1%
Zero shift≤±1%(F.S/yeare)
Connection modeG1/2G1/2 explosion-proof hose
Temperature-40℃~70℃
Explosion-ProofEx dⅡCT6
Power12-36VDC
Dimensions180×150×90mm

OZS30 water ozone detector for detecting ozone concentration in water

Specification
Measure Range0-10.00 ppm
Resolution0.01 ppm
Precision±1%F.S.
Temperature Measure Range0.0-100.0°C/32-212°F
Correction method2 point (0,arbitrary point)
Function option Manual or automatic
Memory function10 groups of datas memory
electrodeCS6930 dissovled ozone electrode
Screen22 * 32 mm multi-line LCD
Power2x1.5V AAA7 battery
Size/Weight164*37*40mm / 100 g
Automatically shut downNo any operation for 6 mins
Level of protectionIP67

Package list :

Ozone derection electrode *1
crossflow sampler *1
7#battery 2 pcs

Prodotti raccomandati
Mettetevi in ​​contatto con noi
Persona di contatto : he